North America (949) 600-6400

Hipot / Dielectric Withstand Testers
General Purpose

Hipot Key Features



19050-70 Hipot Applications

Production test of appliances, instruments and ITE in accordance with IEC, UL, TUV, CSA, EN and other standards including EN60335, EN60950, EN61010, CSA C22.2 No.1010.1, UL3111, UL 1950.

  • ITE / consumer electronic safety testing
  • Transformer safety testing
  • Generator/motor safety testing
  • Non-electronic safety testing
  • Appliance electrical safety testing

Information

» 949 600 6400
» email sales
» email service
» Datasheet
» Comparative Data


See Other Safety Equipment



twitterGet our Newsletter: Click the link below to register.

Sign me up!

 

Follow Us


Facebook - Chroma Systems SolutionsTwitter - Chroma Systems SolutionsRSS - Chroma Systems Solutions

 

 

 

 

 

Hipot Testers - 19050 & 19070 Series

The 19050 series hipot or dielelctric withstanding testers are advanced digital hipots with load and line regulation to ensure measurement integrity. Multi-step capabilities allow users to perform multiple tests in a sequence such as AC hipot followed by insulation resistance testing. The 19070 series is a compact, low-cost entry to hipot testing. Both series include Chroma's patented Open Short Check (OSC) feature, Flashover Detection, Ground Continuity Check, Ground Fault Interrupt (GFI), and Quick Discharge. Both meet UL Hipot Tester Requirements.

19050 General Purpose Hipot Testers

Chroma Hipot Tester - 19053 AC/DC Hipot / Insulation resistance (IR) / 8HV Channel Scan

19052 AC/DC Hipot / Insulation resistance (IR)
CE

19053 AC/DC Hipot / Insulation resistance (IR) / 8HV Channel Scan
UL, TUV, CE

19052 hipot back panel

Our hipot testers have a ground continuity check feature to determine the resistance between the the ground blade and any exposed metal on the product.

See Specs

   

19070 Compact, Low-Cost Hipot Testers

19070 hipot tester - 19073 AC/DC Hipot / Insulation Resistance IR

19071 AC Hipot
UL, TUV, CE

19073 AC/DC Hipot / Insulation Resistance IR
UL, TUV, CE

19073 hipot back panel

These hipot testers are sensitive enough to monitor current spikes even if they don't exceed the max trip current level.

See Specs

 

Ordering Information

19071: AC Hipot Tester
19073: AC/DC/IR Hipot Tester
19073: AC/DC/IR Hipot Tester w/RS485
A190701: Remote control box
A190702: 40kV Test probe
A190344: HV gun (SP02)
A190706: 19" Rack mount kit

19052:AC/DC/IR Hipot Tester
19053: AC/DC/IR/8CH Scan Hipot Tester
A190512: Auto control TR. scan box
A190508: GPIB interface
A190510: Printer interface
A190344: HV gun (SP02)
A150517: 19" Rack mount kit

 

Specifications


Model 19071 19073 19052 19053
Mode AC AC/DC/IR AC/DC/IR AC/DC/IR/Scan
Scanner Unit - - - 8 ports,±phase
Withstanding Voltage Test
Output Voltage AC : 0.05 ~ 5kV AC : 0.05 ~ 5kV , DC:0.05 ~ 6kV
Load Regulation 1% of setting + 5V
Voltage Regulation 2V
Voltage Accuracy 1% of setting + 5 count
Cutoff Current AC : 0.1~20mA, DC : 0.01 ~ 5mA AC : 0.1~30mA, DC : 0.01 ~ 10mA
Current Resolution AC : 1µA, DC : 0.1µA
Current Accuracy 1% of setting + 5 count
Output Frequency 50Hz / 60Hz
Test Time 0.3 ~ 999 sec , continue
Ramp Time 0.1 ~ 99.9 sec, Off
Fall Time 0.1 ~ 99.9 sec, Off
Waveform Sine wave
Insulation Resistance Test
Output Voltage - DC : 0.05 ~ 1kV
Voltage Resolution - 2V
Voltage Accuracy - 5% of setting + 5 count 1.5% of setting + 5 count 1.5% of setting + 5 count
IR Range - 1MΩ ~ 50GΩ 1MΩ ~ 50GΩ 1MΩ ~ 10GΩ
Resistance Resolution - 0.1MΩ 0.1MΩ 0.1MΩ
Resistance Accuracy ≥500V 1MΩ ~1GΩ - 4% of setting + 5 count 5% of setting + 5 count 5% of setting + 5 count
1GΩ ~10GΩ - 7% of setting + 5 count 10% of setting + 5 count 10% of setting + 5 count
10GΩ ~50GΩ - 12% of setting + 5 count 15% of setting + 5 count 15% of setting + 5 count
≤500V 1MΩ ~1GΩ - 7% of setting + 5 count 10% of setting + 5 count 10% of setting + 5 count
≤100V 1MΩ ~1GΩ - 10% of setting + 5 count 10% of setting + 5 count 10% of setting + 5 count
Flashover (ARC) Detection
Setting Mode Programmable setting
Detection Current AC : 1mA ~ 15mA, DC : 1mA ~ 5mA AC : 1mA ~ 15mA, DC : 1mA ~ 10mA
Secure Protection Function
Fast Output Cut-Off 0.4ms after NG
Ground Fault Interrupt 0.5mA ±0.25mA AC, ON/OFF
Panel Operation Lock Present password
Continuity Check 1Ω ± 0.2Ω, ON/OFF
GO/NG Judgment Window
Indication,Alarm GO: Short sound,Green LED; NG: Long sound, Red LED
Data Hold Least tests data memories
Memory Storage 50 instrument setups with up to 20 test steps
Interface
Remote control Input : Start, Stop, Interlock (at 11 pin terminal block only) ; Output : Under test, Pass, Fail
Communication Interface RS485 (Option) RS232 (Standard), GPIB (Option)
General
Operation Environment Temperature : 0°C~40°C, Humidity : 15% to 95% R.H@≤40°C
Power Consumption 300W 500W
Power Requirements 100V/120V/220V/240V (AC ±10%), 50/60Hz
Weight Approx. 12KG Approx. 15KG
Certifications UL, TUV, CE UL, TUV, CE CE UL, TUV, CE

*All specifications subject to change without notice.