19032 Key Features
- Floating Output Design meets EN50191 (19032-P)
- 500VA Power Rating (19032-P)
- Five instruments in one: AC Hipot (hypot), DC Hipot, Insulation Resistance, Ground Bond and Leakage Current (Option)
- Twin-Port™ feature (Patented)
- Programmable output voltage to 5kV AC and 6kV DC
- Insulation resistance to 50GO/1000V DC
- Ground bond up to 30A (Option up to 40A / 60A)
- Open/Short check (OSC) function
- ARC detection (Flashover)
- Password Protected front panel lockout
- Storage of 50 Tests Setups with 100 Steps per setup
- Optional dynamic leakage current auto scanning
- Standard RS-232 Interface
- Standard GB OFF.S.ET KIT, SCANNER Interface
- Optional GPIB Interface
19032 Applications
Compliance testing of IEC, UL, TUV, CSA, EN and other standards including IEC60601-1, UL2601-1, IEC950, UL544, UL60950
- ITE / consumer electronic safety testing
- Transformer safety testing
- Generator/motor safety testing
- Component safety testing
- Non-electronic safety testing
- Appliance electrical safety testing
- Medical equipment safety testing
Information
» 949 600 6400
» email sales
» email service
» 19032 Datasheet
» 19032 Press Release
» Comparative Data
See Other Safety Equipment
- 19050/19070 Series Hipot Testers
- 19035 Wound Component EST Scanner
- 19032 Series Electrical Safety Analyzers
- 19572 Series Ground Bond Testers
|
Need an AC Power Source? Many of our customers use our AC sources to supply stable input voltage for their dynamic leakage current tests. Compatibility: Our AC sources can be controlled, for example, with our 19032 Safety Analyzer using an RS232 interface. |
Get our Newsletter: Click the link below to register.
Follow Us
Electrical Safety Analyzer - 19032 Series
The 19032 series Safety Analyzer able to perform several dielectric tests in one unit including AC/DC Hipot, Insulation Resistance,Ground Bond, Open/Short Check and optional Leakage Current for compliance testing of IEC, UL, TUV, CSA, EN and other standards including IEC60601-1, UL2601-1, IEC950, UL544, UL60950. The time-saving TwinPort™ feature performs Hipot and Ground Bond simultaneously cutting time for these tests in half. The 19032's open / short check function (OSC) checks for an open connection or a DUT short during testing. Open connections may cause a bad DUT to test OK. Screening for shorts prevents damage to the equipment saving potential costs that may occur. These patented features are only available in safety products manufactured by Chroma.
>>> See Specs I See Software
Leakage Current Scanner: Medical Apps
The 19032 Safety Analyzer’s leakage current scanners (A190308) can provide up to 20A input current capability for functional run testing as well as earth, enclosure, patient and line leakage current tests meeting IEC60601-1 compliance requirements.

- Plugs into the19032 for Hipot, Line Leakage Auto Scanning
- Five Different Kinds Human Body RC Network
- Four measurements mode : Normal, Reverse, Single Fault Normal, Single Fault Reverse
- Up to 20A Line Input Current Capability
- Build in A/D and Calibration Data Memory Easy to Install
- Multiple Display Mode Voltage-LC, Amp-LC, VA-LC
- Earth LC, Enclosure LC, Patient LC and Patient Auxiliary LC Test
Leakage Current Scanner Options

Different safety standards have various leakage current test requirements including test methods and maximum current outputs. The 19032 is flexible enough to combine different scanners to satisfy various safety test requirements.
Option |
Hipot |
Ground Bond |
Leakage Current |
|||||||||
Order No. |
Name |
General |
Ports |
Voltage |
Ports |
Current |
Power |
LC |
Earth |
Touch |
Patient |
Patient |
A190301 |
9030A |
Customized |
8 ports |
5KVac |
- |
- |
- |
- |
- |
- |
- |
- |
A190302 |
6000-01 |
Customized |
5 ports |
3 |
30A |
- |
- |
- |
- |
- |
- |
|
A190303 |
6000-02 |
Customized |
3 ports |
5 |
30A |
- |
- |
- |
- |
- |
- |
|
A190304 |
6000-03 |
Customized |
8 ports |
- |
- |
- |
- |
- |
- |
- |
- |
|
A190305 |
6000-04 |
ITE |
L+N to E |
- |
- |
300V/10A |
- |
Y |
- |
- |
- |
|
A190306 |
6000-05 |
Lab/TN |
- |
- |
300V/10A |
P1&P2 |
Y |
Y |
Y |
Y |
||
A190308 |
6000-07 |
Medical |
- |
- |
300V/20A |
P1&P2 |
Y |
Y |
Y |
Y |
||
A190350 |
6000-08* |
Special |
- |
- |
300V/20A |
P1&P2 |
Y |
Y |
Y |
Y |
||
A190307 |
6000-06 |
- |
L+N to E |
2 |
30A |
- |
- |
- |
- |
- |
- |
|
| *Different options have varied specifications. | ||||||||||||
EST Software
EST software controls the analyzer to perform electrical safety integrated tests from the PC. The EST software allows you to save test procedures and data directly as well as exporting the data EXCEL files for quick management reporting and statistical analysis.
|
|
Ordering information
19032: Electrical Safety Analyzer |
A190316: Dummy Load |
Specifications
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||